모형: CCPS
상표: 아이디얼테크닉
원산지: 중국
출력 파워: > 500W
출력 유형: 단일
Input Voltage: Three Phase 380vac
Input Frequency: 50/60hz
Working Principle: Pwm
Power Supply Type: Igbt-Based
Working Mode: Constant Voltage / Constant Current
Display Mode: Lcd
Control Mode: 10-Turn Potentiometers
Protections: Input Lack Phase, Ovp, Ocp, Otp, Short-Circuit Protections Etc., Ocp, Short Circuit And Load Dischargin
Applications: Capacitor Charging, Electrostatic Precipitator, Semiconductor Process, Lab Test / Hipot / Capacitor Charging
Cooling: Forced Air Cooling
Circuit Mode: Pwm
Output Voltage Range: 5 Kv ~ 60 Kv
Output Current Range: 100 Ma ~ 2400 Ma
CCPS 시리즈 고전압 커패시터 충전 DC 전원 공급 장치
개요
CCPS-6U 시리즈 고전압 전원 공급 장치는 CCP-6U 고전압 커패시터 충전 전원 공급 장치의 업그레이드 버전입니다. 그것은 최대 10KW의 출력 전력과 5KV / 10KV / 20KV / 30KV / 40KV / 50KV / 60KV의 출력 전압 레벨을 가진 19인치 6U 표준 랙 장착형 섀시를 사용하여 고전압 충전 전원 공급 장치가 달성했습니다. 고효율, 높은 출력 응답 속도 및 더 빠른 보호 및 시작 자체 복구 유지를 기반으로 랙 장착형 HV 커패시터 충전 전원 공급 장치의 충전 용량이 크게 증가했습니다.
고전압 전원 공급 장치를 충전하는 이 커패시터 시리즈의 전면 패널은 고전압 출력을 보여주는 LCD 미터가 있는 전위차계로 제어됩니다. 이 시리즈의 커패시터 충전 HVPS에는 RS485 인터페이스 및 제어 소프트웨어가 장착되어 커패시터 충전 HVPS의 작동 매개변수를 제어하고 모니터링할 수 있습니다.
전원 공급 장치는 입력 위상 손실, 출력 과전압, 과전류, 과열, 단락 보호 등과 같이 전체 부하에서 HV 커패시터 충전기의 장기적이고 안정적인 작동을 보장하기 위해 보다 포괄적인 보호 기능을 갖추고 있으며, 또한 고전압 전원 공급 장치 및 시험 중인 커패시터를 효과적으로 보호하기 위해 고전압 충전 및 방전 조건을 처리하는 방전 회로를 갖추고 있어야 합니다.
풍모
엘 HV DC 전원 공급 장치 또는 HV 커패시터 충전 전원 공급 장치로 사용할 수 있습니다.
엘 0에서 100%까지 조정 가능한 출력 전압
엘 출력 전력: 평균 충전 @ 5KJ/S 및 최대 충전 전력은 12KW에 도달할 수 있습니다.
엘 정전류 모드에서 충전하고 완전히 충전될 때까지 정전류 모드로 전환합니다.
엘 독특한 이중 절연 시스템, 강력한 간섭 방지 기능.
엘 강제 공기 냉각, 매우 견고한 디자인.
애플리케이션
콘덴서 충전, 집진기, 반도체 공정
안전상의 주의
1. 이 전원 모듈에는 HV 출력이 있으므로 전문가만 작동할 수 있습니다.
2. 반드시 접지를 잘 하신 후 사용하시기 바랍니다.
3. 커패시터 충전 전원 공급 장치는 내부 저장 에너지가 낮습니다. 무부하 작업을 하지 마십시오.
4. 전원 모듈을 깨끗하고 통풍이 잘 되도록 유지하십시오.
5. HV 입력 및 출력 커넥터 또는 HV 부하가 아무 것도 터치하지 않습니다.
Input |
Connection mode |
Three-phase, four-wire (PE), TN-S supply mode |
|
Voltage |
380Vac±10% |
||
Frequency |
50Hz/ 60Hz ± 10% |
||
Current |
As per output power. |
||
Output |
Rated power |
6KW ~ 12KW (Max.) available ** |
|
Output voltage adjusting range |
5KV ~ 60KV available ** (For other output voltages, please contact us for details) |
||
Output current adjusting range |
0A ~ ****mA |
||
Output polarity |
Positive or Negative (both available) Client must choose one output polarity before ordering. |
||
Working mode |
Constant voltage (CV) / Constant current (CC) |
||
Accuracy (C.V.) |
Line regulation |
≤0.5% FS ± 1 digit (Output voltage change rate only caused by changes of input voltage over ± 10% range of variation) |
|
Load regulation |
≤1% FS ± 1 digit (Output voltage change rate only caused by full range load changes) |
||
Accuracy (C.C.) |
Line regulation |
≤0.5% FS ± 1 digit (Output voltage change rate only caused by changes of input voltage over ± 10% range of variation) |
|
Load regulation |
≤0.5% FS ± 1 digit (Output voltage change rate only caused by full range load changes) |
||
Temperature drift |
≤0.03% FS (Output voltage change rate every 8 hours after power on for half an hour) |
||
Ripple (p-p) |
≤0.5% FS (measured @ 80% ~ 100% rated output) |
||
Output cable |
HV connector and line provided by IdealTek. |
||
Efficiency |
≥90% |
||
Setting & Display |
Control mode |
Local |
10-turn potentiometer on front panel. |
Remote (Optional) |
RS485 communication interface. In line with MODBUS-RTU standard. The user can control and monitor the power supply via RS485 connection with computer, E.g: l Power ON / OFF l Output voltage & current setting & reading. l Working state monitoring (constant voltage, constant current, fault) |
||
Display mode |
41/2 LCD digital display |
||
Display error |
≤±0.5%FS ± 1digit (range: 5%~100% of the rated value) |
||
Display resolution |
As per output voltage & current values. |
||
Protection & Monitoring functions |
Input protection |
Input lack phase protection. |
|
Output over voltage protection (OVP) |
Power supply automatically cuts off output and alarms when output has over voltage. |
||
Output over current protection (OCP) |
Power supply automatically cuts off output and alarms when the output has over current. |
||
Over temperature protection (OTP) |
Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds its threshold value. |
||
Output short-circuit protection |
Power supply automatically switches to CC working when the output has short-circuit. |
||
Over-loading capacity |
Withstand working with 1.05 times of rated current. |
||
Noise |
≤65dB |
||
Protection degree |
IP20 |
||
Cooling method |
l Forced air cooling l Forced air cooling + internal water-cooling loop. Direction: The lower part of the left and right sides - In and Top - Out wind. Differ as per output power rating. |
||
Inverter transient protection response time |
≤10us |
||
Working environment conditions |
Ambient temperature |
-5℃~+45℃ |
|
Humidity |
10%~80%(non-condensing) |
||
Height |
≤1000m |
||
Location |
Indoor use only No conductive dust, gas or steam that destroys the insulating medium No severe vibration and shock, good ventilation. |
||
Size (W*H*D) (mm) |
482*265.5*566.5 (19” 6U standard chassis) |
||
Weight |
Approx. 45Kg |
||
|
Front panel description |
||||||||
|
||||||||
No. |
Name |
Function |
Operation / display instruction |
|||||
F1 |
Control cabinet air inlet |
Control cabinet heat dissipation air inlet |
Keep it clean and smooth |
|||||
F2 |
Handle |
For moving and lifting purpose |
|
|||||
F3 |
Mounting hole |
For cabinet installing and fixing |
|
|||||
F4 |
POWER switch |
Supply electric ON/OFF switch |
Switch to ON position è Power ON Switch to OFF position è Power OFF |
|||||
F5 |
VOLTAGE |
Output voltage real-time display |
Digital LED display |
|||||
F6 |
CURRENT |
Output current real-time display |
Digital LED display |
|||||
F7 |
Indicator lights |
Real-time indication of module working state |
Indicator lights display |
|||||
F8 |
Voltage Adj. |
Output voltage adjusting |
Turn as icon, clockwise adjusting for increasing output voltage, anticlockwise adjusting for decreasing output voltage. |
|||||
F9 |
Current Adj. |
Output current adjusting |
Turn as icon, clockwise adjusting for increasing output current, anticlockwise adjusting for decreasing output current. |
|||||
F10 |
Analog port |
232/485 optional port (N/A for this unit) |
Please connect to DB9 port for communication with host. |
|||||
F11 |
Start/Stop (with lock) |
HV output start/stop |
Press down (green light ON) è HV START Press up (green light OFF) è HV STOP |
|||||
F12 |
Charging/Charged |
Charging / Charged state indicator light |
Charging lighted è Under charging. Charged lighted è Charging finished. |
|||||
Front Panel Indicator Lights Description |
||||||||
|
||||||||
No. |
Name |
Function |
Operation / display instruction |
|||||
F13 |
Host indicator light |
Green LED light, lighted when power supply works as host unit under multi-unit parallel-working. Note: host indicator light lighted under single-unit working. |
Indicator lights display |
|||||
F14 |
Slave indicator light |
Green LED light, lighted when power supply works as slave unit under multi-unit parallel-working. Note: slave indicator light not lighted under single-unit working. |
Indicator lights display |
|||||
F15 |
C.V. indicator light |
Green LED light, lighted when power supply works under CV state. |
Indicator lights display |
|||||
F16 |
C.C. indicator light |
Green LED light, lighted when power supply works under CC state. |
Indicator lights display |
|||||
F17 |
Flashover indicator light |
Red LED light, lighted when power supply output has disruptive discharging. |
Indicator lights display |
|||||
F18 |
OC indicator light |
Red LED light, lighted when power supply has internal inverter output over current. |
Indicator lights display |
|||||
F19 |
Out short indicator light |
Red LED light, lighted when power supply has output short-circuits. |
Indicator lights display |
|||||
F20 |
OP indicator light |
Red LED light, lighted when output power of high voltage power supply exceeds the limit. |
Indicator lights display |
|||||
F21 |
Inhibit indicator light |
Red LED light, lighted when power output is prohibited by client's external nodes. |
Indicator lights display |
|||||
F22 |
OT indicator light |
Red LED light, lighted when power supply has internal module over temperature. |
Indicator lights display |
|||||
F23 |
Grid indicator light |
Red LED light, lighted when power supply has input abnormal (i.e.: lack phase or out of scope) |
Indicator lights display |
|||||
F24 |
IGBT indicator light |
Red LED light, lighted when power supply has internal inverter fault |
Indicator lights display |
|||||
F25 |
OV indicator light |
Red LED light, lighted when output voltage goes out of scope. |
Indicator lights display |
|||||
F26 |
Load OC indicator light |
Red LED light, lighted when output current goes out of scope. |
Indicator lights display |
|||||
F27 |
APS indicator light |
Red LED light, lighted when internal auxiliary power supply is working. |
Indicator lights display |
|||||
Back panel description |
||||||||
|
||||||||
No. |
Name |
Function |
Operation / display instruction |
|||||
B1 |
GND |
Main circuit part, connected to earth. |
Separately connected to earth. |
|||||
B2 |
HV cabinet (Feedback) air socket |
For connection of HV cabinet and control cabinet. |
Connect to control cabinet (Feedback) air plug |
|||||
B3 |
Control cabinet (H-power) air socket |
For connection of control cabinet and HV cabinet. |
Connect to HV cabinet (H-power) air plug |
|||||
B4 |
Control cabinet input port |
Remote 485 signal input port |
Leave it unconnected if no 485 signal used. |
|||||
B5 |
Control cabinet DB9 port |
Remote control / reading port |
Connect in external analog signal for remote control / reading (i.e.: 0~10V) |
|||||
B6 |
Control cabinet DB15 port |
Remote start/stop, fault state TTL signal port |
Connect in external start/stop signal (i.e.: 24V) Connect in external analog signal for fault state indication (i.e.: TTL signal) |
|||||
B7 |
Control cabinet (Feedback) air socket |
For connection of control cabinet and HV cabinet |
Connect to HV cabinet (Feedback) air plug |
|||||
B8 |
Cooling fan (temperature-controlled) |
Exhaust fan, controlled by temperature inside the cabinet |
The higher the temperature inside cabinet, the faster the fan speed is. |
|||||
B9 |
IN 480V~600VDC |
Connects to DC480V~600V input |
Red is positive, black is negative. |
|||||
B10/11 |
HV-output |
Negative HV output connector |
Connection port |
|||||
B12 |
Power GND |
Positive output connector |
Connection port |
|||||
B13 |
HV cabinet (H-power) air socket |
For connection of HV cabinet and control cabinet. |
Connect to control cabinet (H-power) air plug |
|||||
Remote interface definition |
||||||||
|
||||||||
B4 Wiring diagram / B5 Internal wiring / B6 Wiring diagram |
||||||||
No. |
Name |
Function |
Operation / display instruction |
|||||
Z-1 |
485-A |
485-A |
485-A |
|||||
Z-2 |
485-B |
485-B |
485-B |
|||||
Z-3 |
Remote ON/OFF state node (optional) (N/A for this unit) |
ON/OFF state node + |
Power OFF, node closed Power ON, node open |
|||||
Z-4 |
|
ON/OFF state node - |
|
|||||
X1 |
Voltage remote control (optional) (N/A for this unit) |
Voltage remote control + |
0-10V signal for 0-15KV output voltage setting |
|||||
X2 |
|
Voltage remote control - |
|
|||||
X3 |
Current remote control (optional) (N/A for this unit) |
Current remote control + |
0-10V signal for 0-1000mA output current setting |
|||||
X4 |
KV |
mA |
P (KW) |
Model |
KV |
mA |
P (KW) |
Model |
5 |
1200 |
6 |
CCPS-(N/P)6kW-5kV |
10 |
1200 |
12 |
CCPS-(N/P)12kW-10kV |
10 |
600 |
6 |
CCPS-(N/P)6kW-10kV |
15 |
800 |
12 |
CCPS-(N/P)12kW-15kV |
15 |
400 |
6 |
CCPS-(N/P)6kW-15kV |
20 |
600 |
12 |
CCPS-(N/P)12kW-20kV |
20 |
300 |
6 |
CCPS-(N/P)6kW-20kV |
30 |
200 |
6 |
CCPS-(N/P)6kW-30kV |
30 |
167 |
5 |
CCPS-(N/P)5kW-30kV |
40 |
150 |
6 |
CCPS-(N/P)6kW-40kV |
40 |
125 |
5 |
CCPS-(N/P)5kW-40kV |
45 |
133 |
6 |
CCPS-(N/P)6kW-45kV |
50 |
100 |
5 |
CCPS-(N/P)5kW-50kV |
50 |
120 |
6 |
CCPS-(N/P)6kW-50kV |
60 |
100 |
6 |
CCPS-(N/P)6kW-60kV |
60 |
200 |
12 |
CCPS-(N/P)12kW-80kV |
|
엘 0 ~ 10V 아날로그 신호 제어 (DB 인터페이스) (+AC)
엘 RS 통신 인터페이스 (RS232 / RS485 선택 사항) (+RC)Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.